{"product_id":"blue-sea-systems-7622100-ml-acr-charging-relay-12v-500a-manual-control-and","title":"Blue Sea Systems 7622100 Ml Acr Charging Relay 12V 500A Manual Control And","description":"\u003ch1\u003eBlue Sea Systems 7622100 12V 500A Ml Acr Charging Relay with Manual Control\u003c\/h1\u003e\u003cp\u003eThe Blue Sea Systems 7622100 ML ACR Charging Relay 12V 500A with Manual Control \u0026amp; Deutsch Connector is a high-quality charging relay designed for managing the charging of two large battery banks. It automatically combines batteries during charging and isolates batteries when discharging and starting the engine.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eManual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicing\u003c\/li\u003e  \u003cli\u003eAutomatically manages the charging of two large battery banks\u003c\/li\u003e  \u003cli\u003eAllows paralleling of battery banks for emergency starting\u003c\/li\u003e  \u003cli\u003e500 Ampere continuous rating to support high-output alternators\u003c\/li\u003e  \u003cli\u003eMagnetic Latch (ML)-ACR draws very low current (\u0026lt;40mA to monitor terminal voltage) in the \"ON\" or \"OFF\" states, and draws moderate current for a very short time when changing state\u003c\/li\u003e  \u003cli\u003eDual sensing-senses charge on both battery banks\u003c\/li\u003e  \u003cli\u003eStart Isolation (SI)-can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics\u003c\/li\u003e  \u003cli\u003eEngine Isolation (EI)-can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output\u003c\/li\u003e  \u003cli\u003eSenses charging on two battery banks\u003c\/li\u003e  \u003cli\u003eLED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation\u003c\/li\u003e  \u003cli\u003e3\/8\"-16 tin-plated copper studs for maximum conductivity and corrosion resistance\u003c\/li\u003e  \u003cli\u003e7\/8\" (22mm) stud length accepts multiple cable terminals\u003c\/li\u003e  \u003cli\u003eSilver alloy contacts provide high reliability for switching live loads\u003c\/li\u003e  \u003cli\u003eLabel recesses for circuit identification\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e  \u003cli\u003eControl Circuit Connection: Deutsch DTM\u003c\/li\u003e  \u003cli\u003eNominal Voltage: 12VDC\u003c\/li\u003e  \u003cli\u003eManual Control: Yes\u003c\/li\u003e  \u003cli\u003eEngine Isolation: Yes\u003c\/li\u003e  \u003cli\u003eMounting: #10\u003c\/li\u003e  \u003cli\u003eStart Assist: Yes\u003c\/li\u003e  \u003cli\u003eStart Isolation: Yes\u003c\/li\u003e  \u003cli\u003eAmperage Operating Current: 13mA\u003c\/li\u003e  \u003cli\u003eAmperage Operating Current When Changing State: \u0026lt;7.0A\u003c\/li\u003e  \u003cli\u003eTerminal Stud Torque: 140 in-lb (15.82 Nm)\u003c\/li\u003e  \u003cli\u003eContinuous Rating: 500A\u003c\/li\u003e  \u003cli\u003eIntermittent Rating: 700A (5 min)\u003c\/li\u003e  \u003cli\u003eCranking Rating 30 Seconds: 1450A DC\u003c\/li\u003e  \u003cli\u003eCable Size to Meet Ratings: 2x (4\/0)\u003c\/li\u003e  \u003cli\u003eLive Current Switching: 300A at 12VDC\u003c\/li\u003e  \u003cli\u003eSwitching Cycles: 100,000\u003c\/li\u003e  \u003cli\u003eTerminal Ring Diameter Clearance: 1.18\" (29.97 mm)\u003c\/li\u003e  \u003cli\u003eTerminal Stud Length: 0.875\" (22.23 mm)\u003c\/li\u003e  \u003cli\u003eTerminal Stud Size: 3\/8\" - 16 (M10)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"#\" onclick=\"window.open('https:\/\/en.wikipedia.org\/wiki\/Blue_Sea_Systems', 'popup', 'height=600,width=800'); return false;\"\u003eWikipedia\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eLearn More\u003c\/h2\u003e\u003cul\u003e  \u003cli\u003e\u003ca href=\"#\" onclick=\"window.open('https:\/\/en.wikipedia.org\/wiki\/Magnetic_latching_relay', 'popup', 'height=600,width=800'); return false;\"\u003eMagnetic Latching Relay\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"#\" onclick=\"window.open('https:\/\/en.wikipedia.org\/wiki\/Alternator', 'popup', 'height=600,width=800'); return false;\"\u003eAlternator\u003c\/a\u003e\u003c\/li\u003e  \u003cli\u003e\u003ca href=\"#\" onclick=\"window.open('https:\/\/en.wikipedia.org\/wiki\/Electronics', 'popup', 'height=600,width=800'); return false;\"\u003eElectronics\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Blue Sea Systems","offers":[{"title":"Default Title","offer_id":48785644716331,"sku":"0632085762216","price":273.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0751\/1428\/3307\/files\/CWR-81426_0632085762216_image1.jpg?v=1759785690","url":"https:\/\/www.ceshowroom.com\/products\/blue-sea-systems-7622100-ml-acr-charging-relay-12v-500a-manual-control-and","provider":"CE Showroom","version":"1.0","type":"link"}